购买二维码:
product description
This product provides all the reagents for cDNA first-strand synthesis, among which reverse transcriptase has lower RNase H activity, higher thermal stability and longer half-life at 50 °C , and can provide more reverse transcription than other reverse transcriptases. The higher full-length cDNA yield of the enzyme can stably generate cDNA representative of the complete gene using the starting RNA. The optimized system significantly improves the sensitivity of the reaction and avoids false negative results. This product can obtain high-fidelity cDNA representing the starting RNA, which is suitable for real-time quantitative RT-PCR and chip experiments that require high sensitivity. The concentration of HI-MMLV Reverse Transcriptase in this product is 200U/μL.
Product Specifications
Reagent composition | ER001-01 (25T) | ER001-02 (50T) | ER001-03 (100T) | storage temperature |
HI-MMLV Reverse Transcriptase(200U/μl) | 25μl | 50μl | 100μl | -20℃ |
5x HI-MMLV Buffer (Mg2+ plus) | 125μl | 250μl | 500μl | |
10x HI-MMLV Solution I | 60μl | 120μl | 240μl | |
RNase Inhibitor (40U/μl) | 25μl | 50μl | 100μl | |
RNase-Free ddH₂O | 1ml | 1ml | 1ml*2 | |
Oligo (dT)16 (10μM) | 60μl | 120μl | 240μl | |
Random Primer (10 μM) | 60μl | 120μl | 240μl | |
dNTP Mixture (25mM each) | 12μl | 25μl | 50μl |
Product Usage
Synthesis of First-Strand cDNA;
Preparation of cDNA Probe;
One-step RT-PCR reaction;
Real Time PCR reaction and chip experiment.
Features
High-efficiency enzyme activity: high-efficiency reverse transcriptase activity, good compatibility for subsequent experiments.
Wide range of applications: applicable to all RNAs, especially RNA templates with complex secondary structures.
Strong stability: higher thermal stability and sensitivity, longer half-life.
Simple and fast: the configuration content is complete, the operation is simple, and high-quality cDNA can be obtained.
Experimental example
The nucleic acid obtained by reverse transcription of ER001 and a domestic brand of reverse transcriptase was used for detection, and the detection results were as follows:
batch A | lot B | |
ER001 | 1146.5ng | 1146.35ng |
Domestic A manufacturer | 1108.45ng | 1160.6ng |
The fluorescent quantitative detection results of the reverse transcribed nucleic acid are as follows:
Using HI-MMLV Reverse Transcriptase Kit ( ER001 ) to amplify the reverse transcribed
fragments, the amplification effect is smaller than that of domestic A company's similar product CT. On the left is ER001,
On the right is the domestic A manufacturer.
Location: Science and Technology Center, High-tech Zone, Shijiazhuang City, Hebei Province
Business Hotline: 186-3213-6937
Headquarters Tel: 0311-82970259
Email: sanshibio@126.com